Welcome Beijing TongTaiLian Technology co.,Ltd !
Tell:010-81513565

Oscillator

TTL-860 automatic temperature control flip oscillator

Model:TTL-860

Range:
Environmental protection, chemistry, fermentation, toxicity identification of solid waste, pharmaceutical, chemical, surface water, industrial waste water, domestic sewage, etc.

Consultation
  • Pntroduction
  • Features
  • Parameter

This product is designed and manufactured in accordance with the requirements of the Solid waste-Extraction procedure for leaching toxicity- Sulphuric acid & nitric acid method (HJ/T 299-2007) and Solid waste-Extraction procedure for leaching toxicity-Acetic acid buffer solution method (HJ/T 300-2007). The sample container designed by the company, which is installed at a 30 degree angle with the rotating shaft. The sample container vibrates while being turned over, increasing the collision and friction between the samples in the container, so that the reaction, dissolution and extraction of the sample in the container are more thorough.

1.Constant temperature control water bath heating mode, even and slow heating
2.Electric control of the gas distribution system
3.Internal electric lifting system optimizes product structure, maintains stable operation of sample rack, internal nitrogen pipeline design, No entanglement in the intake line, Rotatable sample holder, sample on the front the operator to easy to operate, sample holder rotates in any direction, at any angle.
4.Needle valve gas consumption meter controls and displays total gas consumption
5.Water bath and the design of the control part to extend the life of electrical components
6.Teflon coating for corrosion and high temperature resistance

Technical data

  1. Model: TTL-864 、TTL-866 、TTL-868
  2. Sample Treatment: 4 、6、 8
  3. Sample capacity: 2000ml
  4. Sample processing method: Positive inversion,roll, sample holder is tilted 30 degrees,Vibration
  5. Flip speed:Digital display: 0-100 ± 0.2R / minute
  6. Flip speed:Stepless-speed regulation
  7. Flip mode:Flipping, pause, reverse (with manual flip function)
  8. Positive inversion time setting: 1s to 99s,  1min to 99min, 1H to 99H Pause time setting: 1s~ 99s
  9. Vibration function: Vibration frequency: 0-200 times / min  Vibration frequency: 0-100 times / min
  10. 1) stepless speed regulation 2) vibration amplitude: 8mm 3) can be turn on or off
  11. Time setting: 0-30min, 0-30h, 0-300h
  12. Sample management room temperature: Room temperature—50°C (flip speed 30r/min) Accuracy: ±0.5°C